Commercial HVAC
Installation and maintenance of centralised HVAC systems for hotels, offices, retail and facilities.
Commercial HVAC isn't just "big ACs": it's a complex system — outdoor unit, indoor units, central BMS, copper or duct network, sometimes an air-handling unit (AHU). We service every solution in the market for hotels, offices, retail, clinics and industrial sites: Daikin VRV/VRF, chilled-water chillers, air-handling units (AHU/CTA), rooftops, fan coil units and hybrid systems. Maintenance under an annual contract is essential: it keeps performance stable, cuts breakdowns by around 70% and brings the electricity bill down 20-30% compared with a neglected fleet.

Why it matters
Equipment and systems we service
We work on every format commonly installed in Morocco.
- VRV / VRF systems (variable refrigerant flow)
The most advanced solution: one outdoor unit feeds dozens of indoor units (up to 64 on some Daikin ranges). Each zone controls independently, with simultaneous heating and cooling (Heat Recovery). Ideal for hotels, office towers and clinics.
- Chilled-water chillers
For very large projects (hospitals, malls, upscale hotels): a large chiller produces cold water (7 °C) distributed through insulated pipework to fan coil units and AHUs throughout the building. Complex maintenance — must be handled by specialists.
- Air-handling units (AHU)
Full air-treatment equipment: filtration, heating, cooling, humidification and dehumidification before discharge into ducts. Essential for clinics, pharma, mass catering and malls. F7-F9 filters, sometimes HEPA.
- Rooftop units
Single rooftop block combining cooling, heating and fan. Ideal for big-box retail, warehouses and gyms: fast install, simple maintenance (everything in one spot), ducted discharge to the space below.
- Fan coil units
Fan coil units fitted in rooms (under-window, ceiling, ducted or cased). Connected to the chilled/hot water network from the central chiller or boiler. Independent regulation per room.
- BMS (Building Management System)
Central supervisor for the whole system: per-zone temperature reading, remote on/off, operating schedules and fault alerts. Big energy savings when properly configured.
Our intervention process
A simple, transparent flow — from first message to a fully working unit.
- 1Initial audit and study
In-depth technical visit: review of the existing fleet, actual performance, energy consumption, state of filters, units and ductwork. We deliver an audit with weak points and options (upgrade, maintenance, redesign).
- 2Design or upgrade
New projects or extensions: thermal load study, tech choice (VRV, chiller, rooftop), copper or duct network design, electrical hook-up points. Upgrading an existing fleet: outdoor unit swap, adding a BMS, insulation improvement.
- 3Installation and commissioning
Outdoor units mounted on anti-vibration pads, copper network run with professional brazing, vacuum pumping, refrigerant charge, BMS configuration, then unit-by-unit testing.
- 4Scheduled preventive maintenance
Under annual contract: quarterly visits covering filter cleaning/replacement, condenser wash, gas check, sensor calibration, pump testing and BMS log review. Written report after every visit.
- 5Emergency repair 7 days a week
A shutdown at a hotel or clinic = direct loss. Emergency repair 7 days a week for contract customers, prioritised ahead of regular appointments. Diagnosis, repair or interim workaround while waiting for parts.
- 6Follow-up and continuous improvement
Annual summary report: number of faults, electricity consumption (kWh), parts replaced and recommendations to improve energy performance. Goal: lower total cost of ownership (TCO) over time.
Signs you need this service
If you notice any of these symptoms, get in touch fast — waiting typically makes the repair more expensive.
- You're planning a new build or renovation (hotel, office, clinic)
- Aging fleet (R22, equipment > 10 years old)
- HVAC electricity bill unreasonably high
- Customers/staff complaining about temperature gaps between zones
- Repeated failures disrupting operations
- No maintenance contract in place
- Existing BMS outdated or without remote supervision
- Need for an energy audit before upgrade
Frequently asked questions about this service
Any other question? Send us a message on WhatsApp.
What's the difference between VRV/VRF and a chiller?
How often should a hotel VRF be serviced?
Can we add units to an existing VRF?
How long does a mid-size hotel VRF install take?
Can the system be controlled remotely?
What energy savings can I expect from a modern system?
Do you offer a contract with emergency response?
Who handles the electrical and building work?